Tektronix P6015A High-Voltage Probe, 75 MHz Passive, 1000X, 15 kV DC, 3 m Cable

The Tektronix P6015A high-voltage probe is a passive, single-ended 1000X probe with 75 MHz bandwidth and a 15 kV DC rating. It reads ground-referenced high-voltage waveforms. Lost in HCM rents and sells it.

SKU: LIH-P6015A
Category:

Description

High-voltage DC supplies, pulse generators and ignition circuits often produce signals measured against ground. The Tektronix P6015A high-voltage probe brings those signals down to a level the scope input can take. It is a passive, single-ended probe with 1000X attenuation and 75 MHz bandwidth.

Tektronix P6015A high-voltage probe with grey flared handle and dark body, hook tip, ground lead with alligator clip and inline compensation box

P6015A ratings at a glance

Item P6015A
Bandwidth 75 MHz
Attenuation 1000X
Input loading 100 MΩ / 3.0 pF
Cable 3 m nominal
Compensation range 7 to 49 pF
Voltage rating 15 kV DC; 40 kV peak only for specified pulses up to 100 ms, subject to derating
Readout Optional 1R readout coding

DC rating versus pulse rating

The two voltage numbers mean different things. 15 kV DC is the continuous rating. By contrast, 40 kV peak applies only to specified pulses up to 100 ms, and derating still applies. Frequency derating forms a separate limit as well. So check all three before you connect to a test point.

Setting up the Tektronix P6015A high-voltage probe

First, confirm that your scope input works with the probe. Then compensate it with the manufacturer procedure; its compensation range covers 7 to 49 pF. Set the scope to 1000X so the readings scale correctly. Also connect the reference lead to an approved earth point, as the grounding instructions describe. Because the probe reads ground-referenced waveforms, floating nodes call for an isolated probe instead.

Typical work

HV power supply makers can check output behavior at start-up and under load. Similarly, service teams for electrostatic coating or pulse equipment may use it on ground-referenced outputs. Research labs also find a passive divider handy, since it needs no probe power.

Ordering the P6015A

Lost in HCM rents and sells the P6015A, and it arranges service on request. A rental suits a single HV commissioning job or a test campaign. For regular high-voltage work, a purchase may make more sense. To request a P6015A quote from Lost in HCM, give the scope model, the voltage and pulse profile, and whether you need the 1R readout version. You can also compare other oscilloscope probes, visit Tektronix, or contact SMK Vietnam. Follow the manufacturer’s manual and ratings with the Tektronix P6015A high-voltage probe.

P6015A questions

Can it hold 40 kV continuously?

No. The continuous rating is 15 kV DC. The 40 kV peak figure covers specified pulses up to 100 ms only, with derating.

What loading does it put on the circuit?

Input loading is 100 MΩ with 3.0 pF.

Which readout version will I get?

Optional 1R readout coding exists. Confirm the ordered version with Lost in HCM.