Description
Testing a power converter also means pulling real current from it. The Keysight 60502B load module can sink up to 60 A at up to 60 V, within a 300 W limit, and it takes one slot in a 6050A or 6051A mainframe. Lost in HCM lists this obsolete model for rental and sale.

Three modes for three jobs
Constant-current mode holds a fixed draw, which suits supply regulation and battery discharge tests. Constant-voltage mode holds the terminal voltage, so it suits tests of a current source. Finally, constant-resistance mode makes the load act like a resistor. As a result, the source sees a simple ohmic draw that is easy to predict.
Ratings of the Keysight 60502B load module
| Item | Value |
|---|---|
| Inputs | 1 |
| Maximum input voltage | 60 V |
| Maximum input current | 60 A |
| Maximum sinking power | 300 W |
| Mainframe slots required | 1 |
| Compatible mainframes | Keysight 6050A and 6051A |
| Recommended replacement | N3304A |
Control and protection
Also, an analog input lets an outside voltage steer the current in constant-current mode. The mainframe programs the load and reads measurements back, so a scripted rack can log results without manual steps. Five protections guard the unit: overcurrent, overvoltage, overpower, overtemperature and reverse polarity. Still, 300 W is the real ceiling, because 60 V and 60 A together would far exceed it.
Where it works
- Keeping legacy automated test equipment running.
- Checking DC power supplies and converters under load.
- Characterizing batteries and power components.
Moving to the N3304A
Keysight also names the N3304A as the replacement. It needs an N3300A or N3301A mainframe, so a migration changes more than one module. Check commands, cables and rack space before you commit.
Rent or buy this load module
A rental of the Keysight 60502B load module suits a repair or a short verification campaign on a legacy line. A purchase, in contrast, suits a rack that must stay complete for years. Either way, request a quote from Lost in HCM and state your mainframe, the module count and the delivery site. More choices sit in our DC electronic loads category, the Keysight website has official details, and you can contact SMK Vietnam.
60502B questions
What are the limits of the 60502B?
Up to 60 V and 60 A, with a sinking limit of 300 W.
Does it work on its own?
No. It plugs into a 6050A or 6051A mainframe.
Can I rent it?
Rental depends on verified module and mainframe inventory, functional testing and calibration status, so ask Lost in HCM early.
















Reviews