Description
At 20 A, even a short cable steals real voltage. The Keysight N6741B DC power module delivers up to 5 V and 20 A from one output, inside a 100 W limit. It uses a single slot in N6700 and N6705 systems. Lost in HCM lists it for rental and sale.

N6741B ratings
| Outputs | 1 |
|---|---|
| Maximum voltage | 5 V |
| Maximum current | 20 A |
| Maximum power | 100 W |
| Module width | Single slot |
| Output response time | 0.2 ms |
| Sensing | Four-wire remote sense |
Why four-wire sense matters at 20 A
Current through a lead causes a voltage drop, and a 5 V rail has little spare margin. Four-wire remote sensing compensates for that drop at the device under test. Therefore the board sees the voltage you set, not the voltage left after the cable. So run the sense leads to the load terminals, and keep the power leads short and thick.
Programmable behavior for fixture tests
Adjustable slew rate, LIST mode, a data logger and arbitrary waveforms turn this supply into part of the test. For example, you can ramp a rail slowly during a start-up check, then log the current it draws. Keep in mind that commands need about 32 ms to process.
Where the Keysight N6741B DC power module belongs
Low-voltage, high-current rails sit at the heart of many boards. This module feeds those rails during development, and it does so again during production verification. It also powers ATE fixture resources and takes part in multi-rail power sequencing. As a result, embedded, automotive and industrial electronics teams use it most.
Frame and terminal checklist
A compatible mainframe holds up to four independently configured outputs, so check the total power across all of them. Then confirm the firmware, the free slot, the connector block and the leads rated for 20 A. Finally, name the interface and the automation software, because they decide how quickly the station runs.
Book it through Lost in HCM
Lost in HCM supplies the module, while SMK Vietnam shows the listing. To rent or buy the Keysight N6741B DC power module, send your request to Lost in HCM with the rail voltage, current, dates and frame. You can also see more power supplies, read the Keysight website or contact SMK Vietnam.
N6741B questions
Can the N6741B go above 5 V?
No. The maximum voltage is 5 V, so choose another module for higher rails.
How does it hold voltage steady at the load?
Four-wire remote sense measures the voltage at the device and compensates for drop in the load leads.
Can I install several modules in one frame?
Yes, as long as you stay within the slot and total power limits of the compatible N6700 or N6705 mainframe.