Description
Repeating one power test twenty times goes faster when the supply runs the script. The Keysight E36154ABVX power supply is a benchtop DC source rated 30 V, 80 A and 800 W. Its listing adds a scope, AWG, automotive and BenchVue bundle. Lost in HCM quotes it for rental and sale in Vietnam.

Scripted runs with the bundle
The bundle name lists a scope function, an arbitrary waveform generator (AWG), automotive content and BenchVue software. Together, they point to a source that applies a profile, watches the result and logs it. However, the listing does not itemize each license. So ask Lost in HCM what ships with your unit.
Reading 30 V, 80 A and 800 W together
The three ratings do not apply at the same moment. Dividing 800 W by 80 A gives 10 V, so the full 80 A is available only at 10 V or below. At 30 V, the same arithmetic leaves about 26.7 A. Therefore, check the operating curve in the Keysight data sheet before you approve a test plan.
Who books the Keysight E36154ABVX power supply
- Automotive teams that develop control units.
- Engineers who simulate a DC bus for inverters and converters.
- Battery and charging-system researchers.
- Production groups that want a documented, remote-controlled source.
Automotive teams value a source that can disturb a rail on purpose. Meanwhile, storage groups use it as a steady DC stimulus.
Site checks before delivery
An 800 W source still needs sound wiring. First confirm your AC voltage, breaker size and connector. Then size the output leads and fuses for the current you plan to draw. In addition, plan sense wiring when the load sits far from the unit.
Rent for a project or buy for the bench
Rent the Keysight E36154ABVX power supply when a validation run or customer demo has an end date. Buy it when the same bench runs every week. Either way, send your load profile, dates and delivery city, then request a quote from Lost in HCM. You can also browse more power supplies, read the Keysight site or contact SMK Vietnam for help.
E36154ABVX questions
Which BenchVue licenses ship with the unit?
The listing names a BenchVue bundle but does not itemize the licenses. Lost in HCM can confirm them in your quote.
Can I draw 80 A at 30 V?
No. At 30 V the 800 W limit allows about 26.7 A. The full 80 A applies at 10 V or below.
What mains input does it need?
The listing mentions a benchtop unit with AC input, so send your site voltage and connector. Then Lost in HCM will check the match.
















Reviews
There are no reviews yet.