Description
At the top of the voltage range, current drops and caution rises. The Keysight DP5799AH DC power supply pairs 1,500 V with 5 A, which still totals 7,500 W. Lost in HCM lists it for rental and sale in Vietnam.

High voltage, thin current
Thick copper is not the problem here, since 5 A is a light load. Insulation, spacing and discharge energy are the real concerns at 1,500 V. So review isolation, grounding, cabling and protective devices before the first power-up. Keep the setup tidy, label every lead and plan how stored energy will bleed away.
Listing figures
| Item | Listed value |
|---|---|
| Nominal voltage | 1,500 V |
| Nominal current | 5 A |
| Nominal power | 7,500 W |
| Product family | Keysight DP5700 Series system DC power supply |
| AC input | High-line variant (AH) |
Where the Keysight DP5799AH DC power supply fits
Think of electric-vehicle DC bus studies, inverter and converter development, and power-conversion work for energy storage. Engineers in Vietnam can also use it to evaluate modules and subsystems at high voltage. Each of those jobs needs the responsible engineer to check the operating envelope first. Operating curves, ripple and transient response sit in the current Keysight documentation.
Keeping the setup safe
Because the Keysight DP5799AH DC power supply works at 1,500 V, keep everyone who is not part of the test away from the bench. Mark the area, restrict access and then fit protective devices before you switch the output on. As a result, one person can run the test while others stay clear.
Input power and site checks
The AH suffix marks the high-line AC input variant. Compare facility voltage, phase, frequency, connector and breaker with it. Rack ventilation and wiring need review as well. Because high-power equipment may need advance planning, Lost in HCM suggests raising electrical service, lifting and safe shutdown early.
When the site is ready, request a quote from Lost in HCM. Related models sit in the power supplies category, and contact SMK Vietnam can answer other questions.
DP5799AH questions
Why does a 1,500 V model carry only 5 A?
Because the rating is 7,500 W overall. At 1,500 V, that power allows 5 A and no more.
Does the unit suit sale as well as rental?
Lost in HCM lists it for both. Say which you prefer, and mention if used or refurbished stock would be fine.
What photo does the listing use?
It uses a series photo that may show a different model label, so the quote defines the real configuration.
















Reviews
There are no reviews yet.